Additional information
| Type | L370 |
|---|---|
| Display mm / inch | inch, mm, mm + inch |
| Application | Internal measurement |
| Measuring span Mes | 30 mm |
| Measuring range Meb | 70 – 100 mm |
| Range of indication Azb | 69,5 – 100,5 mm |
| Numerical interval Zw | 0,001 / 0,002 / 0,005 / 0,01 / 0,02 / 0,05mm |
| Max. permissible errors G | 0,04 mm |
| Repeatability limit r | 0,02 mm |
| Measuring force F min. | 1,2 N |
| Measuring force F max. | 1,7 N |
| Type of measuring contact movable | HM-Ball Ø 2 mm |
| Measuring contact movable Hb | 8,5 mm |
| Type of measuring contact fixed | HM-Ball Ø 2 mm |
| Measuring contact fixed Hf | 8,5 mm |
| Measuring contact thickness max. | 2,6 mm |
| Measuring depth max. L | 132 mm |
| Weight | 375 g |
| Reference temperature | 20 °C |
| Reference temperature | |
| Storage temperature | -10 – 50 °C |
| Protection class | IP67 |
| Power supply | 2x LR03 (AAA) |
| Interface Bluetooth | order no. 1961-13 |
| Interface Digimatic | order no. 1961-09 + 2482-07 |
| Interface USB | order no. 1961-09 + 2482-05 |
| Interface U-Wave® | order no. 1961-09 + 2482-04 + 2482-01 + 2482-02 |
| Packaging | wooden box order no. 1732-71 |
| Holding unit | order no. 8007-10 |