Additional information
Type | C16200 |
---|---|
Display mm / inch | mm + inch |
Application | External measurement |
Measuring span Mes | 200 mm |
Measuring range Meb | 0 – 200 mm |
Range of indication Azb | 0 – 201 mm |
Numerical interval Zw | 0,2 mm |
Max. permissible errors G | 0,4 mm |
Repeatability limit r | 0,2 mm |
Measuring force F min. | 0,8 N |
Measuring force F max. | 5 N |
Type of measuring contact movable | Hemisphere SR 20 mm |
Measuring contact movable Hb | 98 mm |
Type of measuring contact fixed | Hemisphere SR 20 mm |
Measuring contact fixed Hf | 98 mm |
Measuring contact thickness max. | Ø 20 mm |
Measuring depth max. L | 729 mm |
Weight | 1300 g |
Reference temperature | 20 °C |
Reference temperature | 10 – 30 °C |
Storage temperature | -10 – 50 °C |
Protection class | Not available |
Interface Digimatic | Not available |
Interface USB | Not available |
Interface U-Wave® | Not available |
Wooden box | HK |
Holding unit | Not available |